ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual
Page 78

8-78
8.1.1
77
11
Message structure
Under Message structure, you define the sequence in which the voice messages are transmitted.
To define a message structure:
1. Select the voice message menu as described above.
2. In the voice message menu, press
11
to access the message structure menu option. You see the following
on the display:
3. Press
to select one of the following structure types.
[A] (C/E/P/Z) Specifies the sequence of messages as follows: Common, Event, Partition, Zone
[B] (E/P/Z/C) Specifies the sequence of messages as follows: Event, Partition, Zone, Common
8.1.2
77
22
Voice message labels
Under voice message labels, you define names for zones, partitions, utility outputs and macro keys, and you find out how to play and
record common messages.
To define a voice message:
1. Select the message label menu.
2. In the voice message menu, press
22
to access the message label menu option. You see the following on the
display:
3. You can now enter a name for the voice message for each of the following options:
[1] Common message
[2] Zone message
[3] Partition message
[4] Utility output message
[5] Macro message
Press
or
to select, and confirm with
.
Voice message: message name
Quick-Key Parameter
Default
Range
77
22
11
Common message
Press
11
. You see the following on the display:
The following options are available:
Press
11
to play the common message. You hear the message over the
system loudspeaker. The factory default is “Hello, this is your seurity
system calling"
Press
22
to record a new message. You see the following on the display:
Press
and speak your message into the microphone.
The counter on the
display counts down the remaining seconds until the recording time expires.