Dialer: Parameter
Quick-Key Parameter
Default
Range
55
77 99 22
UD Test
Hr:00
Min:00
00-24 hours
00-59 minutes
Under this option, enter the following: The time for the periodic test call (in 24-hour
format) and the frequency interval.
To program the test time and the intervals for periodic transmissions:
1. Press
22
. You see the following on the display:
2. Enter the time in 24-hour format.
3. Define the frequency interval (D) according to the table below. The first test call
starts on the day of programming.
D Meaning
0
Never
H
Hourly
M
Monthly
1
Daily
2
Every second day
3
Every third day
4
Every fourth day
5
Every fifth day
6
Every sixth day
7
Every seventh day
4. Press
to exit the menu option.
55
77 00
More
This menu determines when the system should transmit the reset message. You can select
between three possibilities:
11
on BTO (bell time out) ,
22
follow zone, 3
3
at disarm