Dialer: Parameter

Quick-Key Parameter

Default

Range

55

77 99 22

UD Test

Hr:00
Min:00

00-24 hours
00-59 minutes

Under this option, enter the following: The time for the periodic test call (in 24-hour
format) and the frequency interval.

To program the test time and the intervals for periodic transmissions:

1. Press

22

. You see the following on the display:

2. Enter the time in 24-hour format.

3. Define the frequency interval (D) according to the table below. The first test call

starts on the day of programming.

D Meaning

0

Never

H

Hourly

M

Monthly

1

Daily

2

Every second day

3

Every third day

4

Every fourth day

5

Every fifth day

6

Every sixth day

7

Every seventh day

4. Press

to exit the menu option.

55

77 00

More

This menu determines when the system should transmit the reset message. You can select
between three possibilities:

11

on BTO (bell time out) ,

22

follow zone, 3

3

at disarm