ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual

Page 26

background image

7-26

System Control:

Quick-Key

Parameter

Default

Range

11

22

01

01

Quick arm

YES

YES/NO

YES:

No user PIN is necessary for activating the system or an area.

NO:

A user PIN is necessary for activating the system or an area. Choose this setting if
the alarm system or an operating panel is accessible to the public or to children.

11

22

02

02

Quick UO

YES

YES/NO

YES:

A user can activate a switch output without a user PIN.

NO:

A user PIN is necessary to activate a switch output.

11

22

03

03

Allow Bypass

YES

YES/NO

YES:

A zone can be omitted (excluded from surveillance) by an authorised user.

NO:

Omitting zones from surveillance is not possible.

11

22

04

04

Quick Bypass

NO

YES/NO

YES:

No user PIN is required for omitting a zone.

NO:

A user PIN is required for omitting a zone.

11

22

05

05

False Code Trouble

YES

YES/NO

YES:

If an incorrect user PIN is entered three times, the operating panel is locked and, if
programmed, an alarm is sent by telephone. Bad PIN input is displayed as a fault on
the operating panel.

NO:

If an incorrect user PIN is entered three times, the operating panel is locked and a
local alarm is sounded.

11

22

06

06

Bell Squawk

YES

YES/NO

YES:

The following signals are emitted by the external sounder to acknowledge
whether you have successfully activated/deactivated the system:

• One tone means that the system is activated.
• Two tones mean that the system is deactivated.
• Four tones mean that the system is deactivated following an alarm.

NO:

No confirmation is made by the sounder.

11

22

07

07

Bell 30/10

NO

YES/NO

YES:

The sounders interrupt the alarm tone for 10 seconds every 30 seconds.

NO:

The sounders emit continuous alarm tones without interruption.

11

22

08

08

Phone Cut Alarm

NO

YES/NO

YES:

Monitors the telephone line and activates the sounder if the telephone line is
cut for the period defined under Phone Line Cut Delay Time. (See also

Phone Line Cut Delay time on page 7-25.)

NO:

The telephone line is not monitored and there is no alarm.

11

22

09

09

3 Minute Bypass

NO

YES/NO

YES:

After the system has been supplied with power, zones are automatically
omitted for 3 minutes to give detectors a chance to stabilise.

NO:

The zones are monitored as soon as the system is activated.

11

22

10

10

Audible Panic

NO

YES/NO

YES:

In the event of a panic alarm, an audible alarm is issued.

NO:

In the event of a panic alarm, it is transmitted by telephone. The system does not
trigger any audible alarms locally.