System Control:
Quick-Key
Parameter
Default
Range
11
22
01
01
Quick arm
YES
YES/NO
YES:
No user PIN is necessary for activating the system or an area.
NO:
A user PIN is necessary for activating the system or an area. Choose this setting if
the alarm system or an operating panel is accessible to the public or to children.
11
22
02
02
Quick UO
YES
YES/NO
YES:
A user can activate a switch output without a user PIN.
NO:
A user PIN is necessary to activate a switch output.
11
22
03
03
Allow Bypass
YES
YES/NO
YES:
A zone can be omitted (excluded from surveillance) by an authorised user.
NO:
Omitting zones from surveillance is not possible.
11
22
04
04
Quick Bypass
NO
YES/NO
YES:
No user PIN is required for omitting a zone.
NO:
A user PIN is required for omitting a zone.
11
22
05
05
False Code Trouble
YES
YES/NO
YES:
If an incorrect user PIN is entered three times, the operating panel is locked and, if
programmed, an alarm is sent by telephone. Bad PIN input is displayed as a fault on
the operating panel.
NO:
If an incorrect user PIN is entered three times, the operating panel is locked and a
local alarm is sounded.
11
22
06
06
Bell Squawk
YES
YES/NO
YES:
The following signals are emitted by the external sounder to acknowledge
whether you have successfully activated/deactivated the system:
• One tone means that the system is activated.
• Two tones mean that the system is deactivated.
• Four tones mean that the system is deactivated following an alarm.
NO:
No confirmation is made by the sounder.
11
22
07
07
Bell 30/10
NO
YES/NO
YES:
The sounders interrupt the alarm tone for 10 seconds every 30 seconds.
NO:
The sounders emit continuous alarm tones without interruption.
11
22
08
08
Phone Cut Alarm
NO
YES/NO
YES:
Monitors the telephone line and activates the sounder if the telephone line is
cut for the period defined under Phone Line Cut Delay Time. (See also
Phone Line Cut Delay time on page 7-25.)
NO:
The telephone line is not monitored and there is no alarm.
11
22
09
09
3 Minute Bypass
NO
YES/NO
YES:
After the system has been supplied with power, zones are automatically
omitted for 3 minutes to give detectors a chance to stabilise.
NO:
The zones are monitored as soon as the system is activated.
11
22
10
10
Audible Panic
NO
YES/NO
YES:
In the event of a panic alarm, an audible alarm is issued.
NO:
In the event of a panic alarm, it is transmitted by telephone. The system does not
trigger any audible alarms locally.