ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual
Page 27

7-27
System Control:
Quick-Key
Parameter
Default
Range
11
22
11
11
Buzzer
Bell
NO
YES/NO
YES:
If the system is activated internally and an alarm is triggered, an alarm is
sounded for 15 seconds on the operating panels before the system activates
the external sounders and the alarm is transmitted by telephone.
NO:
If the system is activated internally and an alarm is triggered, the external
sounders and the telephone line are activated immediately.
11
22
12
12
Fire Temporal Pattern
YES
YES/NO
YES:
The fire signals of the internal and external sounders are three increasing alarm
tones followed by a pause.
NO:
The fire signals of the internal and external sounders are two seconds of continuous
tone followed by two seconds’ pause.
11
22
13
13
Code Grand Master
NO
YES/NO
YES:
Only a user with Grand Master authority can change user PINs and the time
and date.
NO:
Users at the Master and Manager level can also change user PINs and the
time and date.
11
22
14
14
Audible Jamming
NO
YES/NO
Refers to Jamming Time, which is described on page 7-30.
YES:
If the defined jamming time is reached, the ABUS wireless alarm system
activates the sounders. (See Jamming Trouble, page 7-32.)
NO:
Jamming does not trigger an audible alarm.
11
22
15
15
Technician Tamper
NO
YES/NO
YES:
The program PIN is required for resetting a tamper alarm. First, the OK
message must be received from the detector or the tamper zone must be
closed.
NO:
A tamper alarm is reset with the OK message of the detector or when the
tamper zone is closed.
11
22
16
16
Technician Reset
NO
YES/NO
YES:
Following an alarm, the program PIN must be entered to be able to reactivate the
system.
NOTE:
Before the Ready LED can light up, all zones in this area must be closed.
NO:
The alarm system can be activated immediately following an alarm if all zones are
closed and the Ready LED is on.
11
22
18
18
Summer/Winter Clock
YES
YES/NO
YES:
The ABUS wireless alarm system automatically puts its clock forward
one hour forward in spring (last Sunday in March) and one hour back in
autumn (last Sunday in October).
NO:
No automatic time adjustment
11
22
19
19
Forced Keyswitch Arming
YES
YES/NO
YES:
If the system or an area is activated by a key-switch, all open zones are
automatically omitted from monitoring. The remaining zones are monitored. The
system/area is monitored in every case.
NO:
The system/area can be activated only if all zones are closed and the system/area
is ready for activation.