ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual
Page 61

7-61
Controls
Quick-Key Menu
option
Default
55
66
02
02
FM Enable
NO
YES: Enables FM (= Follow Me) transmission.
(See also Follow Me, page 7-64.)
Enable this option to transmit alarms as voice messages by telephone. Disable this
option if the system has no telephone connection, since otherwise a telephone
error is reported.
NO: No FM transmission is possible.
55
66
03
03
U/D Enable
NO
YES: Enables remote dialling of the up/download software by modem.
Enable this option if you want to remote-service the system by modem and
software. Disable this option if the system has no telephone connection, since
otherwise a telephone error is reported.
NO: No remote dial-in is possible.
55
66
05
05
Dial Tone
YES
YES: The ABUS wireless alarm system checks before dialling whether a dial
tone is available and does not dial until a dial tone is detected. If the system is
connected to a PBX, set this option to “No”.
NO: The ABUS wireless alarm system dials without waiting for a dial tone.
55
66
07
07
User initiated call
YES
YES: To enable up/download programming, the user has to confirm this every time
on the system.
NO: Upload/download programming is possible without confirmation by the user.
55
66
08
08
Call Back U/D
YES
YES: The ABUS wireless alarm system calls the programmed U/D callback
number when the call is set up. This setting represents extra security.
NO: No callback is made.
55
66
09
09
Auto Batch
NO
YES: The ABUS wireless alarm system calls the U/D callback number for an
automatic download at a previously defined time.
NOTE:
To ensure that the Auto Batch setting works:
The U/D computer must be switched on, connected with a telephone line, and have
upload/download software.
-AND-
The call must be released.
NO: Auto Download mode is activated.