beautypg.com

ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual

Page 48

background image

7-48

7.4 33

Outputs

Under Outputs, you program the relay and transistor outputs of the system. You link different system events to the activation of the
outputs. The following is an overview of the menu options according to their sequence in the Outputs menu:

33

11

Define, page 7-48

33

22

Output A, page 7-53

33

33

Output B, page 7-53

To access the Outputs menu:

In the installer menu, press

33

or press

or

until you find the number of the Utility Output [3]

menu option. Press

. The first submenu appears on the display:

You are now in the

Outputs menu and can access the submenus as described in the following sections.

7.4.1 33

11

Define

Under Define, you can program specific outputs.

To access the Define menu:

1. Select the Outputs menu as described on page 54.

2. Under Outputs, press 11 to access the Define menu option.
3. Enter a two-digit number for the output you want to program. Enter a zero (0) and a number from 1 to 9 (for

example: 01, 02 etc.). Then press

. You see the following on the display:

4. You can now program the selected switch output. After defining the event to be followed by the output,

press

and continue with the displayed menus to program the areas (only for outputs that follow an

area; see page 7-52).

Define

Quick-Key Parameter

33

11

UO

UO 00

Follow nothing

The switch output follows no event and is therefore deactivated.

33

11

UO

UO 11

Follow system

This menu option shows system events.

33

11

UO

UO 11

01

01

Bell Follow

This switch output is activated if an external sounder is activated. In the case of a
sounder delay, this output is activated following the expiry of the delay period.

33

11

UO

UO 11

02

02

No Telephone Line

The switch output is activated if a break in the telephone line is detected. It is deactivated
after the telephone line fault is removed.

33

11

UO

UO 11

03

03

Communication Failure

The switch output is activated if no contact to the command centre can be established. It is
deactivated after a successful call is made to the command centre.

This manual is related to the following products: