ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual
Page 50

7-50
Define
Quick-Key Parameter
33 11 UO
UO 22
08
08 Duress Follow
The switch output is activated if a forced alarm is triggered on the operating panel
in one of the selected areas.
To deactivate this switch output, see the user menu under
Duress Reset ([2] [6]).
(This is described in the ABUS User Guide.)
33
11
UO
UO 22
09
09
Buzzer Follow
The switch output is activated if an operating panel activates its buzzer in the
selected area(s).
33 11 UO
UO 22
10
10 Exit/Entry Follow
The switch output is activated if the entry/exit delay time is activated in the selected
area(s).
33 11 UO
UO 22
11
11 Fire Trouble Follow
The switch output is activated if a fire fault is detected in the selected area(s).
33
11
UO
UO 22
12
12
Day (Zone) Trouble
The switch output is activated if a Day Zone fault is detected in the selected area(s).
33 11 UO
UO 22
13
13 General Trouble Follow
The switch output is activated if any fault is detected in the selected area(s).
33
11
UO
UO 22
14
14
Stay Follow
The switch output is activated if one of the selected areas is INTERNALLY activated.
33 11 UO
UO 22
15
15 Tamper Follow
The switch output is activated if tampering is detected in the selected area(s).
33
11
UO
UO 22
16
16
Disarm Follow
The switch output is activated if one of the selected areas is deactivated.
33
11 UO
UO 22
17
17 Bell Follow
The switch output is activated if the sounder is triggered in the selected area.
33
11
UO
UO 22
18
18
Bell Stay Off
The switch output is activated as follows:
• If the system is activated externally (AWAY), the switch output is activated
as soon as the sounder is triggered in the selected area.
• If the system is activated internally (STAY), the switch output is not
activated if the sounder is triggered in the selected area.
NOTE:
If an alarm is to be triggered in a zone that is assigned to more than one area, and if one of
the areas is in an externally activated state (while the other area is in an internally activated
state), the switch output is activated in the event of an alarm.
In an internally activated state, a 24-hour zone does not activate this switch output.
33
11
UO
UO 22
19
19
Zone Bypass
The switch output is activated if a zone is omitted in the selected area(s) and the area(s)
are internally or externally activated.