background image

7-25

Timers:

Quick-Key Parameter

Default

Range

11

11

22

Exit/Entry delay 2

Exit and entry delay times of Group 2. Make these settings as for Group 1.

11

11

22

11

Entry delay 2

45 seconds

1-255 seconds

Entry delay time for Group 2.

11

11

22

22

Exit delay 2

45 seconds

1-255 seconds

Exit delay time for Group 2.

11

11

33

Bell Timeout

03 minutes

01-90 minutes

Duration of external sounder(s) during an alarm

NOTE:

In some countries, the duration of the external sounder must be limited to 3 minutes. Check
the regulations for your country.

11

11

44

Bell Delay

00 minutes

00-90 minutes

Defines the delay between the detection of the alarm situation and sounding the alert
on the sounder (of the system or the external sounder). A sounder delay is
particularly useful if an alarm was first triggered by telephone without the burglar
noticing it.

11

11

55

AC Off Delay Time

05 minutes

0-255 minutes

In the event of a power failure, this menu option defines the delay time (0-255
minutes) before the event is reported or before the switch output is activated.

11

11

66

Phone Line Cut Delay

05 minutes

01-20 minutes

In the event of a telephone line fault, this menu option defines the delay time before
the event is reported or before the switch output is activated.

11

11

99

Accessory Superv. time

255 minutes

000-255 minutes

Defines the monitoring time for accessories such as interior and exterior wired
sounders. To avoid false alarms, make sure that the monitoring time of the receiver

(menu item

11 33 33

) is longer than the monitoring time for accessories.

7.2.2

11

22

System Control

Under System Control, you make settings that control specific functions of the complete system.

NOTE:

Under this menu item, it is important that you press the lozenge button

before exiting so that your data is saved. If you

exit the menu by pressing

, your settings are lost.

To access the System Control menu option:

1. Select the main menu System as described on page 7-24.

2. In

the

System menu, press

22

to get to System Control. You see the following on the display:

3. Select and configure the settings in the System Control menu as follows:

This manual is related to the following products: