System Control:

Quick-Key

Parameter

Default

Range

11

22

20

20

Pager

NO

YES/NO

Enables alphanumeric output of system events on a pager. The number of the pager
must be programmed like a Follow-Me number.

YES:

For the activated/deactivated event and the alarm event, the system sends
information to the pager.

NO:

The system transmits no events to pagers.

11

22

21

21

Arm Pre-Warning

NO

YES/NO

YES:

For the system, or every area for which an automatic activation function was
programmed, a warning signal of 255 seconds is generated on the operating
panels and the alarm system prior to activation.

During this countdown, you can enter a valid user code to delay automatic
activation of the system/area by 45 minutes.

If activation of the system/area is delayed in this way, automatic activation of the
system is deactivated on the following days.

The 255-second warning does not apply to automatic internal activation.

NO:

The system/area for which an automatic activation function is programmed is
activated automatically every day, regardless of whether automatic activation is
delayed or not.

11

22

22

22

Low Battery Arm

YES

YES/NO

YES:

The system can be activated even if the standby batteries are not fully
charged or inserted.

NO:

The system cannot be activated in the event of a battery fault.

11

22

23

23

Eng. Tamper

NO

YES/NO

YES:

The system cannot be activated following a tamper alarm. The program
PIN first has to be entered.

NO:

The system can be reactivated following a tamper alarm without the entry
of the program PIN.

11

22

24

24

Blank Display

NO

YES/NO

YES:

In operation mode, the LCD display is switched off for one minute after the
last input. To reactivate the display, a valid user PIN must be entered.

NO:

The LCD display is always on.

11

22

25

25

24 Hour Bypass

YES

YES/NO

YES:

A user can omit a 24-hour zone.

NO:

A user cannot omit a 24-hour zone.

11

22

26

26

IMQ Install

NO

YES/NO

YES:

If a zone is open when the system is activated, the system is activated but an alarm
is generated when the exit delay time expires.

NO:

Open zones are automatically omitted following expiry of the exit delay time.

11

22

27

27

Grand Master
Authority/Partition

YES

YES/NO

YES:

Areas and authority levels can be changed by the installer in the installer menu and
in the user menu using a Grand Master pin.

NO:

Areas and authority levels can only be changed by the installer in the installer menu.

11

22

28

28

Disarm Stop FM

YES

YES/NO

YES:

Forwarding of calls is stopped when the system is deactivated.

NO:

Forwarding of calls is continued even if the system is deactivated.

NOTES:

If a block lock is used, you can deactivate the system only if the block lock is opened.

However, if the system is deactivated by telephone, the calls are continued.