Follow Zone
This menu option lists events for a zone.
33
11
UO
UO 33
11
Zone Follow
The switch output is activated if the selected zone is triggered. The state of the alarm
system is not relevant.
33
11
UO
UO 33
22
Alarm Follow
The switch output is activated as soon as the selected zone triggers an alarm.
33
11
UO
UO 33
33
Arm Follow
The switch output is activated if the selected zone is triggered via the system.
33
11
UO
UO 33
44
Disarm Follow
The switch output is activated if the selected zone is deactivated via the system.
33
11
UO
UO 44
Follow User Code
The switch output is activated if a valid user code is entered.
The switch output is activated by the user in the function menu Activities/Operate Output,
buttons [2][1].
To enable you to activate the output with a PIN, the PIN must be authorised for the
activation of a switch output.
Press
or
to select the equivalent code from the 32 available user codes.
Press
to switch between [Y] YES and [N] NO.
NOTE:
The switch output is activated by the entry of a user code only if the utility output setting is
set to N in the system macros. If quick output is activated, no user code is required.
Define
Quick-Key
Parameter
33
11
UO
UO 22
20
20
Auto Arm Alarm
The switch output is activated if an alarm was activated during the prewarning time during
an auto-arm process.
33
11
UO
UO 22
21
21
Zone Loss Alarm
The switch output is activated if a wireless zone is lost.