ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual

Page 44

background image

7-44

7.3.3 22

33 Zone Testing

Under Testing, you can check the correct functioning of zones.

To access the Testing menu:

1. Select the Zones menu as described on page 7-36.

2. In the Zones menu, press 33 to access the Testing menu option. You see the following on the display:

22

33

11

Wireless Communication Test

Runs a communication test between the wireless detector and the ABUS wireless

alarm system.

1. Press

11

. You see the following on the display:

2. To run the communication test, trigger the detector. If reception is successful, the

alarm system shows the signal strength. A successful test is confirmed by a beep
on the alarm system.

NOTE:

For successful communication, the signal strength (= displayed value) should be
higher than the noise level of the transmitter (see also page Calibration).

3. Press

or

to select the zone number of the next wireless detector.

4. Press

to exit the menu option.

22

33 22

Soak Test

Some wireless detectors tend to trigger alarms more than others. The Soak Test
was developed to test these detectors over a longer period without triggering an
alarm.

Up to 8 zones can be programmed for the Soak Test. A zone programmed for the
Soak Test is omitted for 14 days while the alarm system is active. If no alarm is
triggered by this detector for 14 days, the tested zone is automatically reintegrated
in the system.

If one of the zones programmed for the Soak Test sends an alarm within these 14
days, the alarm system does not trigger an alarm but registers a fault message
instead. You can see the fault message in the user menu.

The 14-day period for the joint test of alarm lines is then set to zero and restarted.

To add a zone to the Soak Test:

Press

22

. You see the following on the display:

To add a zone to the Soak Test, press

. You see the following on the display:

Enter the zone number (e.g., 01 for Zone 1) and press

. The menu jumps to the

next assignment number.

To add a second zone to the Soak Test, press

and repeat the above procedure

- OR -

Press

to return to the previous menu.

If you enter zone number 00, no zone is assigned to the Soak Test.