Receiver

Under Receiver, you can make settings that control the radio receiver of your ABUS wireless alarm system.

To access the Receivers menu option:

1.

Select the main menu System as described on page 7-24.

2.

In the System menu, press

33

to go to the Receivers menu option. You see the following on the display:

3.

Select and configure the settings in the Receiver menu as follows:

Receiver:

Quick-Key Parameter

Default

Range

11

33

11

Calibration

During calibration, the radio receiver measures the level of the electromagnetic background
noise. The lower the level, the better the selected installation location. Additionally, the level
set decides the strength of the electromagnetic field above which the alarm system
interprets this as a conscious tamper attempt.

Range of level: 00-99.

Press

11

. The following appears on the display and specifies the current level:

To conduct a new automatic measurement, press

and select [Y] YES.

After measurement is complete, the new level is displayed as follows:

To confirm the new level, press

OR:

To change the level manually, enter the desired level and press

.

NOTES:

To ensure that a measured low value (due to the environment) does not trigger a fault alarm
in later operation, you can set the level higher as the measured value. Never reduce the
measured level, since this will lead to a fault alarm in later operation.

11

33

22

Jamming Time

No Jamming
detection

None, 10, 20 or
30 seconds

The jamming time specifies the time within one minute in which the level of the background
noise can be above the value measured under “Calibration” (or above the manually set
value).

NOTE:

A fault is displayed only if the “Audible Jamming” option was enabled in the system control.

11

33

33

Supervisory Time

0 hours

0-7 hours

The wireless detectors automatically send a message to the ABUS wireless alarm system
every 65 minutes. This message also contains information on the battery state and the
current alarm state. The wireless alarm system can now monitor whether these messages
are regularly transmitted. Within the set monitoring time, at least one message per detector
must be transmitted.

NOTES:

The setting “0 hours” aborts monitoring.

You are recommended to set the monitoring time to a minimum of 3 hours.