Editing
Quick-Key Parameter
22
44
44
Delete a partition
Deletes a selected partition. All zones assigned to this partition are also deleted.
1. Press
44
.
2. Press the cursor keys to select the area you want to delete.
3. Press
to switch between [Y] YES and [N] NO and press
.
4. Press
to exit the program.
7.3.5
22
55
Cross Zone
Default: No cross-zone dependency
Cross-zone dependency is an ideal function for making a system safer against false alarms. Using cross-zone dependency, two zones
have to trigger an alarm within a specific period and in a defined or undefined sequence before the alarm system generates an alarm.
NOTE:
The ABUS wireless alarm system enables you to program 10 of these zone pairs.
To access the Cross Zone menu:
1. Select the Zones main menu as described on page 7-36.
2. In the Zones menu, press
55
to get to the Cross Zone menu option. You see the following on the display:
3. Press
to define the first pair (01) of cross-dependent (interdependent) zones.
4. You select a zone pair by entering the number of the first zone followed by the number of the second zone.
If necessary, press
or
to switch between the first and second zone.
NOTE:
Zones defined as mutually interdependent are considered as a zone pair. They both have to report an
alarm before the system triggers an alarm.
5. Press
to define how the ABUS wireless alarm system deals with cross-zone dependency.
6. Select and configure the paired zones as follows:
Crossing
Quick-Key Parameter
Default
22
55
11
None
No dependency is defined between the zones.
22
55
22
Ordered
The ABUS wireless alarm system triggers an alarm if the first zone and then the second
zone triggers an alarm within the defined period. The alarm system triggers no alarm if the
zones trigger in the opposite order.
22
55
33
Not ordered
The ABUS wireless alarm system triggers an alarm if both zones are triggered within the
defined period. Which of the two zones is first triggered is irrelevant.