beautypg.com

ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual

Page 46

background image

7-46

Editing

Quick-Key Parameter

22

44

44

Delete a partition

Deletes a selected partition. All zones assigned to this partition are also deleted.

1. Press

44

.

2. Press the cursor keys to select the area you want to delete.

3. Press

to switch between [Y] YES and [N] NO and press

.

4. Press

to exit the program.

7.3.5

22

55

Cross Zone

Default: No cross-zone dependency
Cross-zone dependency is an ideal function for making a system safer against false alarms. Using cross-zone dependency, two zones
have to trigger an alarm within a specific period and in a defined or undefined sequence before the alarm system generates an alarm.

NOTE:

The ABUS wireless alarm system enables you to program 10 of these zone pairs.

To access the Cross Zone menu:

1. Select the Zones main menu as described on page 7-36.

2. In the Zones menu, press

55

to get to the Cross Zone menu option. You see the following on the display:

3. Press

to define the first pair (01) of cross-dependent (interdependent) zones.

4. You select a zone pair by entering the number of the first zone followed by the number of the second zone.

If necessary, press

or

to switch between the first and second zone.

NOTE:

Zones defined as mutually interdependent are considered as a zone pair. They both have to report an
alarm before the system triggers an alarm.

5. Press

to define how the ABUS wireless alarm system deals with cross-zone dependency.

6. Select and configure the paired zones as follows:

Crossing

Quick-Key Parameter

Default

22

55

11

None

No dependency is defined between the zones.

22

55

22

Ordered

The ABUS wireless alarm system triggers an alarm if the first zone and then the second
zone triggers an alarm within the defined period. The alarm system triggers no alarm if the
zones trigger in the opposite order.

22

55

33

Not ordered

The ABUS wireless alarm system triggers an alarm if both zones are triggered within the
defined period. Which of the two zones is first triggered is irrelevant.

This manual is related to the following products: