ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual

Page 40

background image

7-40

Parameter

Quick-Key Parameter

Default

Range

22

22

44

ZZ

ZZ

+

01

01

Exit/Entry 1

Armed/internal

A zone programmed as Exit/Entry 1 must not be opened during the exit delay time
without an alarm being triggered. However, the zone must be closed before the exit
delay time expires. If the zone is opened when the alarm system is active, the entry
delay time of Group 1 (to be programmed under System/Timers) is started. The
area of the wireless alarm system must be deactivated in this time. If not, an alarm
is triggered following the expiry of the delay period. Detectors trained for a zone
with this property are usually fitted to front and side doors. This zone must be
closed at the moment of activation. If this cannot always be guaranteed, choose the
zone type Exit(OP)/Entry

22

22 44 ZZ

ZZ

+

02

02

Exit/Entry 2

Armed/internal

See above. However, for zones of this type, the times of Group 2 apply.

22

22

44

ZZ

ZZ

+

03

03

Exit(OP)/Entry

Default for zone 1

Armed/internal

Zone type Exit(OP)/Entry behaves like zone type Exit/Entry 1 except that the
zone does not have to be closed at the moment of activation. However, the zone
must be closed before the exit delay time expires, or otherwise there is an alarm.
This zone type is usually assigned to opening contacts on front and side doors.

22

22

44

ZZ

ZZ

+

04

04

Entry follower

Armed/internal

Zone type Entry follower does not trigger an alarm if an entry delay time is started
first. If no entry delay is active, this zone triggers an alarm immediately if the area is
activated. This zone type is usually assigned to motion sensors that monitor the
entrance area, in addition to opening contacts on the entrance doors.

22

22

44

ZZ

ZZ

+

05

05

Instant

Armed/internal

If the area is active, the Instant zone type triggers an alarm immediately when the
zone is opened. This zone must not be opened during the entry and exit delay
period. This is the usual zone type for motion and opening sensors that are not in
the entrance area.

22

22

44

ZZ

ZZ

+

06

06

I+Exit/Entry 1

(Interior + Exit/Entry 1)

Default for zone 2

Armed

The I+Exit/Entry 1 zone type is similar to zone type Exit/Entry 1. However, this zone type
is not monitored for an internally activated system.

IMPORTANT INFORMATION:

To shorten the exit delay time, press

twice. This sets the entry delay time to 0. If

this zone is now opened, there is an immediate alarm.

22

22

44

ZZ

ZZ

+

07

07

I+Exit/Entry 2

Interior+Exit/Entry 2)

Armed

See above. However, for zones of this type, the times of Group 2 apply.

22

22

44

ZZ

ZZ

+

08

08

I+Exit(OP)/Entry

(Interior+Exit(OP)/Entry)

Armed

The I+Exit(OP)/Entry zone type is similar to zone type Exit(OP)/Entry. However, this zone
type is not monitored for an internally activated system.