Set datum for the Z-axis:

Position the tool so that its tip touches the top surface
of the part.

Using the keypad, enter "0" into the "Z" field
(or press the Z = 0 softkey).

Press the

ENTER

key.

Press the

USE

key.

Datum has now been established for X, Y, and Z

It's a good idea to test the datum setting before programming. To confirm
that the new datum is correct:

Raise the tool and move the table until
both the X- and Y-axes displays read
"0.0000."

Lower the tool until it touches
the part.

Check the tool's position—the lower left
corner of the part should be directly
beneath the center point of your tool.

Now check the readout. If the Z-axis display says "0.0000," then the datum is
accurate. If a value other than 0.0000 appears in the Z-axis display, repeat the
procedure for establishing datum.

You can quickly
move to Datum
for X and Y by
pressing the
POS key. Check
that your
position is
0.0000 ABS
for both X and
Y, then press
the GO key.