12 cleaning and maintenance - scan system, Cleaning and maintenance - scan system, Leaning and maintenance – Xerox 6204 EN User Manual
Page 151: Ystem
Wide Format Copy System User Guide
145
12 Cleaning and Maintenance -
Scan System
Cleaning and maintenance - Scan System
For the Scan System to do its best job, the Platen Glass, Document Drive Rolls, Backer Roll,
Calibration Strip, and Document Feed Tray must be kept clean. This requires some daily and
monthly cleaning and maintenance activities.
Daily activities:
• Clean the Platen Glass, Document Drive Rolls, and Backer Roll. See the “Cleaning
the Platen Glass and Document Drive Rolls” section on the next page.
• Inspect the Document Feed Tray and clean as required.
Monthly activities:
• Clean the Calibration Strip. See the "Cleaning the Calibration Strip" section.
• Inspect the Platen Glass for chips and scratches. If the Platen Glass is chipped or
scratched, and these defects are visible in the scanned images, call XEROX service.