Clean cal zone position: cleaning position – Xerox 6204 EN User Manual
Page 138
10 Main Menu
132
Wide Format Copy System User Guide
Clean CAL Zone
The CLEAN CAL ZONE (Clean Calibration Zone) provides the user with a quick way to move the
Calibration Motor to the cleaning position. There are two selections CLEANING POSITION AND
HOME POSITION.
CLEAN CAL ZONE
POSITION: CLEANING POSITION
Clean Cal Zone Screen
Component Tests
The COMPONENT TESTS option of the SCANNER DIAGNOSTICS menu provides a sub-menu
of the following menu choices:
• MOTOR SPEED - Enables the Customer Service Engineer to adjust the Scan
System motor speed and correct magnification errors in the process direction. The
diagnostic password is required for this function.
• LEAD EDGE/TRAIL EDGE - Enables you to execute the lead edge/trail edge
diagnostic.
• SENSORS - Enables you to display the current state of the Scan System optical
paper sensors and the thick document sensor.
• MOTOR COMMUNICATIONS - Enables a document motor communications
loopback test to assist in diagnosing a Scan System problem.
• DOCUMENT MOTOR - Enables you to stop and start the document handler motor.
• LAMP - Enables you to turn the lamp on and off and receive a feedback from the
illumination sensor.
• CALIBRATION MOTOR - Enables you to test the calibration zone motor.
To access the COMPONENT TESTS menu:
1. Press
the
Menu
key. The MAIN MENU screen is displayed.
2. Press
the
Next
key until DIAGNOSTICS is highlighted.
3. Press
the
Enter
key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is
displayed.
4. Press
the
Next
key until SCANNER DIAGNOSTICS is highlighted.
5. Press
the
Enter
key to highlight SCANNER DIAGNOSTICS. The SCANNER
DIAGNOSTICS menu screen is displayed.
6. Press
the
Next
key until COMPONENT TESTS is highlighted.
7. Press
the
Enter
key to select COMPONENT TESTS. The COMPONENT TESTS
menu screen is displayed. The black arrows indicate that the menu contains more
options than are visible. The selected option is highlighted.