2. Copier-specific Adjustments

(2) Press the [IMAGE] button on the Control Panel. Press the [SHARPNESS] button.

Press the [SOFT] button to soften the copy image.

After softening the copy image, copy and check the copy image quality.

If further image quality adjustments is necessary, go to the next step.

(3) Enter adjustment mode [05].Change the values for codes [604] to [606], [922], [1737] to [1741], [1757],

[7795] and [7807] to [7809] to adjust the default value for the sharpness intensity.

* Decreasing the sharpness intensity will minimize moiré.

Color mode

Original mode

[05] code

Recommended

value

Accepta

ble value

range

Default

Text / Photo

05-604

Text 05-605

Photo 05-606

User custom

05-922

Black

Image smoothing

05-7809

Set a value smaller

than 128.

28 to 127

0 to 255

128

Text / Photo

05-1737

Text 05-1738

Printed image

05-1739

Photo 05-1740

Map 05-1741

Full color

User custom

05-7795

Set a value smaller

than 128.

28 to 127

0 to 255

128

Text / Photo

05-1757

Text 05-7807

ACS / Black

Photo 05-7808

Set a value smaller

than 128.

28 to 127

0 to 255

128

* The smaller the value is, the weaker the sharpness intensity becomes. The larger the setting value is, the

stronger the sharpness intensity becomes.

Changing the values for these codes will change the sharpness intensity, when the "Sharpness" indicator in

the "IMAGE" menu is set to the center. Remember that 1 step of the indicator will increase or decrease the

sharpness intensity by 25. If the sharpness intensity of the center value is changed, each step of the

indicator will be changed accordingly. (For instance, if the center value is decreased by 25 (softer), the

value of each step of the indicator will also be decreased by 25 (softer).)

However, the range of adjustment values that is valid for sharpness level change is from -100 to +100 of

the total of the setting value of the adjustment code and that of the indicator. For instance, if the setting

value of the adjustment code is "103" (-25 from the default value), the limit of the steps in the soft side of

the indicator is "-3". If the step is set at "-4", the image quality will not be changed.