5. Scanning-specific Adjustments

‰

Procedures

* You can start with any of the procedures. But it is recommended to perform the procedures in order, as listed

below. You can use one procedure in conjunction with another. But if this changes the image quality more

than required or loses the effectiveness of the adjustment, restore the settings made in the previously used

procedure to the original ones. Then use other procedures.

* Both the service technician and the user can use procedure (1).

* Only the service technician must use procedure (2).

(1) When scanning the original, press the [COMMON SETTING] button on the Control Panel. Press the [+]

button to increase the sharpness intensity.


After increasing the sharpness intensity, scan the original and check the scanned-in image quality.

With the sharpness intensity set to the maximum, if further image quality adjustments are still necessary, the

service technician must use the next procedure.

(2) Enter adjustment mode [05]. Change the values for codes [1086 to 1088] and [840 to 843] to adjust the

sharpness intensity.

Color mode Original mode [05] code

Recommended value

Acceptable

value range

Default

Text/Photo 05-840

Text 05-841

Black

Photo 05-842

Text 05-1086

Printed image

05-1087

Full color

Photo 05-1088

Gray scale

---

05-843

Set a value larger than 128.

0 to 255

128

*

Setting "0" provides the softest image, while setting "255" provides the sharpest image.

‰

Caution after the adjustment

The adjustment may possibly cause moiré. In addition, when text and thin lines in a light-colored background

are scanned, the background around the text or line may be eliminated. Therefore, carefully perform the

adjustment, while checking the scanned-in image.