beautypg.com

Toshiba e-Studio Imaging 6520c User Manual

Page 108

background image

e-STUDIO5520C/6520C/6530C

© 2008 TOSHIBA TEC CORPORATION All rights reserved

2-74

2. Copier-specific Adjustments

(2) Enter the adjustment mode [05]. Adjust each setting value for the custom mode to satisfy the user’s request.

• Select the necessary adjustments from the procedures below.

To match the density level of background scanned with the original glass equivalent to that

of background scanned with the RADF

(a) Enter the adjustment mode [05]. Change the value for the code [7025] to adjust the reproducibility of

the background of the image scanned with the RADF. The larger the setting value is, the darker the

background becomes. The smaller the setting value is, the lighter the background becomes.

[05] code

Recommended value

Acceptable

range

value

Default

05-7025

Set a value smaller than 128 to
make the background darker.

Set a value larger than 128 to make
the background lighter.

0 to 255

128

To copy while eliminating the background color (to adjust the reference value for the

background density adjustment)

* This adjustment is effective when you do not copy the dark color of the background of an original.

(a) Enter the adjustment mode [05]. Change the values for codes [7236] and [7237] to make the range

correction operation fixed.

• The code to be set differs depending on the density mode. Select the [05] code for the target

original mode and change the value to "0".

Original

mode

Density mode

[05] code

Recommended

value

Acceptable

range value

Default

Automatic 05-7236

Text/Photo

Manual 05-7237

0 0,

1

1

* Explanation for setting values

Setting

value

Range correction

operation

0 Fixed
1 Varied

This manual is related to the following products: