5. Scanning-specific Adjustments

‰

Procedures

* The service technician must perform all adjustments.

(1) Enter adjustment mode [05]. Change the values for codes [880 to 883] to adjust the gamma curve balance

of the low-, medium- and high-density areas.

Color mode Original mode [05] code Subcode

Recommended value

Acceptable

value range

Default

Text/Photo 05-880 0/1/2

Text 05-881

0/1/2

Black

Photo 05-882

0/1/2

Gray scale

---

05-883

0/1/2

Set a value smaller than 128
to decrease the density.

Set a value larger than 128
to increase the density.

0 to 255

128

* Set the value in increments of approximately 20, while checking the scanned-in image until the optimum

value is obtained.

* The subcode varies according to the area where the density is adjusted. Refer to the table below and set

the subcode for the area to be adjusted.

Subcode

Area where the density is adjusted

0 Low-density

area

1 Medium-density

area

2 High-density

area

* Gradation in the Black mode will vary, if the medium-density area is mainly adjusted. But remember that

adjusting the low- or high-density area will rarely affect the gradation in the Black mode.

‰

Caution after the adjustment

Nothing in particular.