beautypg.com

Toshiba e-Studio Imaging 6520c User Manual

Page 27

background image

e-STUDIO5520C/6520C/6530C

© 2008 TOSHIBA TEC CORPORATION All rights reserved

1-17

1. General Adjustments – Copying, Printing and e-Filing (Output from Box)

To Have Uniform Variations in the Image Quality after Return from the Auto Power Save Mode:

Change the value of the [08] code [571] to change the conditions for starting image quality control (shorten

the period of time the MFP is left unused) after the MFP was recovered from the auto power save mode, so

that the image quality control will be easily performed.

Value for

08-571

Period of time the MFP is left unused before starting image quality control

0

3 minutes or longer (image quality control is performed before the paused job is
resumed)

1

5 minutes or longer (image quality control is performed before the paused job is
resumed)

2

7 minutes or longer (image quality control is performed before the paused job is
resumed)

3

10 minutes or longer (image quality control is performed before the paused job is
resumed)

4

15 minutes or longer (image quality control is performed before the paused job is
resumed)

5

20 minutes or longer (image quality control is performed before the paused job is
resumed)

6

30 minutes or longer (image quality control is performed before the paused job is
resumed)

7

45 minutes or longer (image quality control is performed before the paused job is
resumed)

8

60 minutes or longer (image quality control is performed before the paused job is
resumed)

9

90 minutes or longer (image quality control is performed before the paused job is
resumed)

10

120 minutes or longer (image quality control is performed before the paused job is
resumed)

11

150 minutes or longer (default value - image quality control is performed before the
paused job is resumed)

12

180 minutes or longer (image quality control is performed before the paused job is
resumed)

13

240 minutes or longer (image quality control is performed before the paused job is
resumed)

14

300 minutes or longer (image quality control is performed before the paused job is
resumed)

15

360 minutes or longer (image quality control is performed before the paused job is
resumed)

Do not disable the Auto shut off mode timer setting ("0" is set for 08-206) while the Auto

power save timer setting is set to invalid ("0" is set for 08-205). If both settings are set to

invalid, this equipment does not enter the energy saving mode so it is always in the ready

status. Due to this, image quality control according to the period of time the MFP is left

unused is not performed regardless of the setting value of 08-571.

• After setting the value for code 08-571, forcibly perform image quality control, as follows:

Enter adjustment mode [05], select code [396], and then press the [START] button.

This manual is related to the following products: