Toshiba e-Studio Imaging 6520c User Manual
Page 286
e-STUDIO5520C/6520C/6530C
© 2008 TOSHIBA TEC CORPORATION All rights reserved
5-20
5. Scanning-specific Adjustments
(2) Enter adjustment mode [05] to adjust the values in the Custom mode, in order to obtain the image quality the
user desires.
• Select the necessary value for [05] code in the table below.
Color mode
[05] code
Adjustment
Acceptable
value range
Default
05-7425
Range correction (Automatic density
adjustment)
1
05-7426
Range correction (Manual density
adjustment)
0 to 1
0
05-7470 Sharpness
adjustment
128
05-7475
Manual density adjustment center value
128
05-7478
Automatic density adjustment
128
05-7480
Gamma curve balance adjustment
0 to 255
128
05-8371
Fine adjustment of black density
0 to 4
0
05-8404
Background processing offset adjustment
(Automatic density adjustment)
128
Black
05-8409
Background processing offset adjustment
(Manual density adjustment)
0 to 255
128
05-8334
Range correction adjustment (Automatic
density adjustment)
1
05-8365
Range correction adjustment (Manual
density adjustment)
0 to 1
0
05-8370
Background adjustment
0 to 50
50
05-8371
Fine adjustment of black density
0 to 4
0
05-8372
RGB conversion method selection
0 to 3
0
05-8373 Saturation
adjustment
128
05-8375 Sharpness
adjustment
128
05-8380
Manual density adjustment center value
128
05-8381
Manual density adjustment light step value
20
05-8382
Manual density adjustment dark step value
20
05-8389
Background processing offset adjustment
(Automatic density adjustment)
128
Full color
05-8394
Background processing offset adjustment
(Manual density adjustment)
0 to 255
128
* For further information regarding the codes, refer to the Service Manual/Service Handbook.
Select the code for the Custom mode option, in order to adjust the value for [05] code in the
Custom mode. Never adjust any values for [05] code in existing original mode.
After adjusting the value in the Custom mode, use the next procedure.