Toshiba e-Studio Imaging 6520c User Manual
Page 26
e-STUDIO5520C/6520C/6530C
© 2008 TOSHIBA TEC CORPORATION All rights reserved
1-16
1. General Adjustments – Copying, Printing and e-Filing (Output from Box)
Explanation
The image contrast may vary, depending on the date and time when copying or printing is performed or the type
of copy/print job. To constantly maintain image quality, shorten the waiting period until image quality control is
performed.
Procedures
* The service technician must perform the adjustment in accordance with the procedures below.
(1) Enter setting mode [08]. Change the value for code [570], [571], [572] or [2508] to specify the best interval
during which image quality control should be performed, according to use of the MFP.
The MFP is installed in a place where the temperature and humidity vary widely:
Make adjustment by either of the following procedures (A) or (B).
(a) Set "1" (value
× 5%R.H.) for code 08-570 to increase the frequency of image quality control, in response
to a change in humidity.
* Image quality control will be performed, when the relative humidity changes in accordance with the
specified difference from the previous image quality control. If the difference in the relative humidity
exceeds the specified value, image quality control is performed first. Then a copy or print job will be
performed.
Value for 08-570
Difference in relative humidity
1 5%R.H.
2 10%R.H.
(default)
(b) Set "5" or "3" for code 08-2508 to increase the frequency of image quality control, in response to a
change in humidity.
* Image quality control will be performed, when the drum temperature changes in accordance with the
difference from the previous image quality control. If the difference in the drum temperature exceeds
the specified value after a print job is performed, image quality control is performed.
Value for 08-2508
Difference in drum temperature
3
3°C
5
5°C
7
7°C
(default)
• After setting the value for code 08-571 by procedure (a) or (b), forcibly perform image quality control, as
follows:
Enter adjustment mode [05], select code [396], and then press the [START] button.