beautypg.com

Toshiba e-Studio Imaging 6520c User Manual

Page 123

background image

e-STUDIO5520C/6520C/6530C

© 2008 TOSHIBA TEC CORPORATION All rights reserved

3-3

3. Printer-specific Adjustments


(1) Perform automatic calibration to correct variations in image density.

* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other

words, an administrator is authorized to operate automatic calibration. But the [USER] option can also be
selected to allow the user to operate it. Refer to the MFP Management Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.

* Perform each adjustment for 600dpi and 1200dpi.

* Use steps (a) through (j) to perform the automatic calibration.

(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [ADMIN] tab.
(c) Enter an administrator password of 6 to 10 digits. Press the [OK] button.
(d) Press the [GENERAL] button.
(e) Press the [CALIBRATION] button.
(f) Press the [600dpi PRINT] or [1200dpi PRINT] button.
(g) Press the [CALIBRATION] button to print out the test chart.
(h) Place the printed test chart on the original glass.
(i) Press the [START] button to perform calibration. When the calibration comes to an end, the message

"Scanning and calibrating" will disappear.

(j) The message "Is a result made to reflect?" will appear. Press the [YES] button.


‰

Caution after the adjustment

When image quality control is repeatedly performed, the color balance may slightly vary due to an error even in

the same environment.

PCL6

PS3

Mac

XPS