Toshiba e-Studio Imaging 6520c User Manual
Page 282
e-STUDIO5520C/6520C/6530C
© 2008 TOSHIBA TEC CORPORATION All rights reserved
5-16
5. Scanning-specific Adjustments
Procedures
* The service technician must perform all adjustments.
(1) Enter adjustment mode [05]. Change the values for codes [1075 to 1077] to adjust the black density of a
scanned-in image.
Color mode Original mode [05] code
Recommended value
Acceptable
value range
Default
Text 05-1075
Printed image
05-1076
Full color
Photo 05-1077
Set a value larger than 0.
0 to 4
0
* Setting "0" provides the lightest black, while setting "4" the darkest.
Caution after the adjustment
The adjustment may possibly provide the extremely dark background. Therefore, carefully perform the
adjustment, while checking the scanned-in image.