Toshiba e-Studio Imaging 6520c User Manual
Page 110
e-STUDIO5520C/6520C/6530C
© 2008 TOSHIBA TEC CORPORATION All rights reserved
2-76
2. Copier-specific Adjustments
To adjust the changing amount of "ACS ADJUSTMENT" indicator
(a) Enter the adjustment mode [05]. Change the values for codes [934] and [937] to adjust the changing
amount of the "ACS ADJUSTMENT" indicator per step for the manual density mode. The larger the
setting value is, the larger the changing amount per step becomes. The smaller the setting value is,
the smaller the changing amount per step becomes.
Base
original
mode
Moving
direction in
indicator
[05] code
Recommended value
Accepta
ble
range
value
Default
Light step
05-934
Text/Photo
Dark step
05-937
Set a value smaller than 20 to
make the changing amount
smaller.
Set a value larger than 20 to
make the changing amount
larger.
0 to 255
20
* Light step: Moving the indicator to the [
] side.
Dark step: Moving the indicator to the [
] side.
If the setting value is too small or too large, the density level may not be changed (the
number of steps moved may not be detected) even if the user moves the indicator on the
touch panel.
To adjust gamma balance in medium- and high-density areas
(a) Enter the adjustment mode [05]. Change the value for the code [949] to adjust the gamma balance in
each of medium- and high-density areas.
Base
original
mode
[05] code
Subcode
Recommended value
Accepta
ble
range
value
Default
Text/Photo 05-949
1/2
Set a value smaller than
128.
0 to 255
128
* Set the value in increments of approximately 20, while checking the copy image until the optimum
value is obtained. Note that gradations (density level) in the medium- and high-density areas may
be reversed with some setting values.
* Subcodes to be entered differ depending on the target density area. Refer to the table below to enter
the subcode for the area to be adjusted.
Subcode
Area where the density is
adjusted
1 Medium-density
area
2 High-density
area