beautypg.com

Scanning-specific adjustments – Toshiba e-Studio Imaging 6520c User Manual

Page 267

background image

e-STUDIO5520C/6520C/6530C

© 2008 TOSHIBA TEC CORPORATION All rights reserved

5-1

5. Scanning-specific Adjustments

5.1 To Clearly Scan Text

(To reduce noise around text)

Before the adjustment

After the adjustment

If the original is scanned in the Full color
mode or the Gray scale mode, noise may occur
in text or edges of a solid filled area.

The image quality is maintained, while noise
is being reduced.

‰

Explanation

When an original is scanned in the Full color or the Gray scale mode, the data compression may cause noise

(toner scattering) around text or the edges of a solid filled area. Adjust the compression rate or change the scan

resolution, in order to obtain a better scanned-in image, while reducing noise.

* This adjustment will have an effect on the image scanned in the Full color mode (including the Auto color

mode) or the Gray scale mode.

‰

Procedures

* You can start with any of the procedures. But it is recommended to perform the procedures in order, as listed

below. You can use one procedure in conjunction with another. But if this changes the image quality more

than required or loses the effectiveness of the adjustment, restore the settings made in the previously used

procedure to the original ones. Then use other procedures.

* Both the service technician and the user can use this procedure. However, step (3) in the procedure must be

performed only by the service technician.

(1) When scanning the original, press the [COMMON SETTING] button on the Control Panel. Select "LOW"

from among the compression rate options.

* [MID] is selected from among the compression rate options by default.

After changing the compression rate, scan the original and check the scanned-in image quality.

If further image quality adjustments are still necessary, use procedure (2).

This manual is related to the following products: