Removing the clock/calendar battery, Figure 149 removing the clock/calendar battery, Lift battery off – Nortel Networks BCM1000 User Manual
Page 290: Motherboard
290
Chapter 20 Replacing data cards and processing hardware
P0607659 02
Removing the clock/calendar battery
This section explains how to correctly remove the clock/calendar battery.
1
If you still have access to the Unified Manager, shut down the system using the Shutdown
command. For details refer to
“Shutting down the system software” on page 238
. Otherwise,
skip to step 2.
2
Set up the BCM1000 for maintenance, as described in
“Shutting down the system hardware”
3
Attach one end of the grounding strap to your wrist and the other end to a grounded metal
surface.
4
If the system has a redundant power supply, you may need to remove this before removing the
battery. Refer to
Chapter 19, “Replacing a power supply,” on page 269
.
5
Use your finger to carefully lift the battery out of the socket.
For the location of the battery socket, refer to
Figure 149
Removing the clock/calendar battery
Caution:
Do not use any type of tool to remove the battery.
The battery is located
under the edge of the
power supply
Front of unit