Ata 2 does not function, Checking the wiring – Nortel Networks BCM1000 User Manual
Page 235

Chapter 15 Troubleshooting
235
Installation and Maintenance Guide
If the emergency telephone is connected to the CTM, use the following procedure:
1
Check that the system has a CTM installed.
2
Check that there is no dial tone at the emergency telephone.
3
Replace the CTM.
ATA 2 does not function
If the Business Communications Manager ATA 2 does not function. Follow these steps to
troubleshoot the problem.
1
Make sure there is ac power connected to the ATA 2 unit.
2
Make sure that ATA 2 is in the Tones OFF mode. (For Data Applications only.)
3
Correctly configure the ATA 2 telephone port for data communication.
4
Allow sufficient start up time.
5
Assign the prime line.
6
Assign a ringing line if required, for example, auto-answer modems, FAX).
Checking the wiring
Check the following connections:
•
ATA 2 to the terminal.
The resistance must be 200 ohms or less for data applications and 1,300 ohms or less for voice
applications.
•
Business Communications Manager hardware to ATA 2.
The wiring must be equivalent to 800 m of 0.5 mm wire (2,600 ft. of 24 AWG) or less. Do not
use bridge taps and loading coils between the Business Communications Manager hardware
and Business Communications Manager ATA 2.
•
External line to the Business Communications Manager system.
Ensure the external line is correctly connected to the BCM1000 and make sure there is dial
tone.