Installation and Maintenance Guide

Chapter 13
Installing Analog Terminal Adapters

This chapter provides installation instructions for the Analog Terminal Adapter 2 (ATA 2).

The ATA 2 connects a standard analog voice device or data communication device to the Business
Communications Manager system. Examples of analog voice devices are single-line telephones or
answering machines. Examples of data communication devices are modems and fax machines.

The ATA 2 provides on-premise service only (unexposed plant only).

Before installation

Before you attempt to install an ATA 2 device, ensure that your system and environment meet the
requirements listed in this section.

Environmental requirements

Check the following environment requirements for the ATA 2:

Operating requirements

The following are requirements for operating other analog or data communication devices:

Line voltage (120 V)

102 – 132 V ac

Line voltage (230 V)

207 – 253 V ac

Temperature

0 – 50°C (32 – 122°F)

Relative humidity

5% – 95% non-condensing

Bridge taps

Not allowed between the Business Communications Manager system
loading coils and Business Communications Manager ATA2

Ringing signal (North America):

Frequency Voltage:

20 Hz ± 1 Hz

80 V rms ± 10%

Ringing signal (Europe):

Frequency voltage:

25 Hz ± 1 Hz

75 V rms ± 10%

Ringer equivalence number

3

Battery feed voltage

- 48 V dc ± 10%

Loop current

20 mA minimum

FIC code

OL13ABC