Chapter 13, Installing analog terminal adapters, Before installation – Nortel Networks BCM1000 User Manual
Page 217: Environmental requirements, Operating requirements, Chapter 13, “installing analog terminal adapters, Chapter 13, “installing analog, Chapter 13 installing analog terminal adapters

217
Installation and Maintenance Guide
Chapter 13
Installing Analog Terminal Adapters
This chapter provides installation instructions for the Analog Terminal Adapter 2 (ATA 2).
The ATA 2 connects a standard analog voice device or data communication device to the Business
Communications Manager system. Examples of analog voice devices are single-line telephones or
answering machines. Examples of data communication devices are modems and fax machines.
The ATA 2 provides on-premise service only (unexposed plant only).
Before installation
Before you attempt to install an ATA 2 device, ensure that your system and environment meet the
requirements listed in this section.
Environmental requirements
Check the following environment requirements for the ATA 2:
Operating requirements
The following are requirements for operating other analog or data communication devices:
Line voltage (120 V)
102 – 132 V ac
Line voltage (230 V)
207 – 253 V ac
Temperature
0 – 50°C (32 – 122°F)
Relative humidity
5% – 95% non-condensing
Bridge taps
Not allowed between the Business Communications Manager system
loading coils and Business Communications Manager ATA2
Ringing signal (North America):
Frequency Voltage:
20 Hz ± 1 Hz
80 V rms ± 10%
Ringing signal (Europe):
Frequency voltage:
25 Hz ± 1 Hz
75 V rms ± 10%
Ringer equivalence number
3
Battery feed voltage
- 48 V dc ± 10%
Loop current
20 mA minimum
FIC code
OL13ABC