Emergency telephone does not function, Figure 98, System status monitor led settings record – Nortel Networks BCM1000 User Manual
Page 234: Table 43, Led display screen settings

234
Chapter 15 Troubleshooting
P0607659 02
3
To set the parameters for the System Status Sanity check, click the LED Settings tab.
The LED Settings record appears.
Figure 98
System Status Monitor LED Settings record
lists the values on the LED Settings screen.
Emergency telephone does not function
If the emergency telephone is connected to the system, use the following procedure:
1
Check the power LED on the ASM 8 to check that the ASM 8 is receiving power.
2
Check that the emergency telephone has dial tone.
3
Check the external line and emergency telephone connections.
4
To avoid damage to the emergency telephone, connect the telephone directly to the external
line and check for dial tone.
5
Replace the MSC.
Table 43
LED Display screen settings
Attribute
Values
Description
Version
Read only.
The current version of the LED monitoring application.
Reset
Yes, No, N/A
Use Yes to allow the system status monitor board to reset the
computing platform in the event that the sanity check fails the
user set parameters.
Sanity Time
60-255
Default: 240
The time in seconds between sanity checks.
Timeouts
0-254
Default: 10
The number of sanity checks that must fail before the system
status monitor sends a reset signal to the computing platform.