Installation and Maintenance Guide

Wiring the and connecting the RPI

The maximum two-way DC loop resistance for power pairs, including interconnections for each
base station, is 75 ohms. You need one or two power pairs between the RPI and the base station.
The number of power pairs depends on the wire size of the power pair and the distance between
the base station and the RPI.

The maximum cable distances allowed between the RPI and the base station depend on the size of
wire you use. Refer to

Table 36

.

Connecting the RPI

Connect the power pairs to the correct connectors.

Figure 73

shows the location of the input and

output connectors on the RPI connector printed-circuit board.

Figure 73

RPI connector printed-circuit board

Caution:

Do not run unprotected power cables outdoors.

Table 36

Cable distances

Wire size

Single pair

Double pair

0.6 mm (22 AWG)

800 m (2,500 ft.)

1200 m (4,000 ft.)

0.5 mm (24 AWG)

500 m (1,500 ft.)

1000 m (3,000 ft.)

Caution:

When you use two power pairs, connect both pairs with the same polarity.

OBIX1 OBIX2

OBIX3 OBIX4

OBIX9

OBIX10 OBIX11 OBIX12

OBIX5 OBIX6

OBIX7 OBIX8

OBIX13

OBIX14 OBIX15 OBIX16

IBIX1

IBIX3

IBIX2

IBIX4

0B1X1 0B1X2 0B1X3 0B1X4

0B1X9

0B1X10 0B1X11 0B1X12

0B1X5 0B1X6 0B1X7 0B1X8

0B1X9

0B1X13 0B1X14 0B1X15

IBIX

4

IBIX

3

IB

IX

2

IBIX

2