Wiring the and connecting the rpi, Figure 73, Rpi connector printed-circuit board – Nortel Networks BCM1000 User Manual
Page 197: Table 36, Cable distances, Wiring the, And connecting the rpi, Connecting the rpi
![background image](/manuals/191815/197/background.png)
Chapter 12 Installing the Companion system
197
Installation and Maintenance Guide
Wiring the and connecting the RPI
The maximum two-way DC loop resistance for power pairs, including interconnections for each
base station, is 75 ohms. You need one or two power pairs between the RPI and the base station.
The number of power pairs depends on the wire size of the power pair and the distance between
the base station and the RPI.
The maximum cable distances allowed between the RPI and the base station depend on the size of
wire you use. Refer to
.
Connecting the RPI
Connect the power pairs to the correct connectors.
shows the location of the input and
output connectors on the RPI connector printed-circuit board.
Figure 73
RPI connector printed-circuit board
Caution:
Do not run unprotected power cables outdoors.
Table 36
Cable distances
Wire size
Single pair
Double pair
0.6 mm (22 AWG)
800 m (2,500 ft.)
1200 m (4,000 ft.)
0.5 mm (24 AWG)
500 m (1,500 ft.)
1000 m (3,000 ft.)
Caution:
When you use two power pairs, connect both pairs with the same polarity.
OBIX1 OBIX2
OBIX3 OBIX4
OBIX9
OBIX10 OBIX11 OBIX12
OBIX5 OBIX6
OBIX7 OBIX8
OBIX13
OBIX14 OBIX15 OBIX16
IBIX1
IBIX3
IBIX2
IBIX4
0B1X1 0B1X2 0B1X3 0B1X4
0B1X9
0B1X10 0B1X11 0B1X12
0B1X5 0B1X6 0B1X7 0B1X8
0B1X9
0B1X13 0B1X14 0B1X15
IBIX
4
IBIX
3
IB
IX
2
IBIX
2