Chapter 18 Adding or replacing a cooling fan

P0607659 02

Troubleshooting fan operation

There are two LEDs on the front of the BCM1000 and one on the front of the expansion cabinet
that can be used to assess fan function. Refer to

Figure 120

.

Figure 120

Business Communications Manager operational LEDs

Table 46

describes the possible states of the fan and temperature LEDs.

Removing a fan from the BCM1000

The BCM1000 can have one or two fans.

If the BCM1000 has two fans, before you shut down the system, determine which fan has failed.

1

If you still have access to the Unified Manager, shut down the system using the Shutdown
command. For details refer to

“Shutting down the system software” on page 238

. Otherwise,

skip to step 2.

2

Set up the BCM1000 for maintenance, as described in

“Shutting down the system hardware”

on page 239

.

3

Attach one end of the grounding strap to your wrist and the other end to a grounded metal
surface.

Table 46

Fan and temperature LEDs on the server

LED Label

Description

Green LED On

Red LED On (Only)

Temperature

Temperature is below threshold. Temperature is in alarm status.

One of the problems could be that one of
the fans has failed.

Fans

All installed fans are working

There is a problem with a minimum of
one fan.