beautypg.com

Analog loop, System equipment and supplies, Basic hardware – Nortel Networks BCM1000 User Manual

Page 121: Optional equipment

background image

Chapter 5 Installing the BCM1000

121

Installation and Maintenance Guide

Analog loop

The following parameters must be met for an analog loop.

maximum dc loop resistance of 208

maximum cable length (0.5 mm or 24 AWG) of 1220 m (4000 ft.)

System equipment and supplies

Use the following checklists to ensure that you have all the required equipment.

Basic hardware

The Business Communications Manager system consists of some combination of the following
hardware:

BCM1000

BCM1000e

media bay modules

telephones and other communication devices such as fax machines

cabling for connections between hardware units

You can place a maximum of three media bay modules in the BCM1000. You must install an
BCM1000e if you require more than three media bay modules.

Optional equipment

The following equipment can be added to the system to support specific requirements beyond the
base unit:

Station auxiliary power supply (SAPS)

Central answering position (CAP or CAPN) module to as many as five M7324/M7324N
telephones in the system

Business Communications Manager Analog Terminal Adapter 2
(ATA 2) if connecting analog equipment to a digital media bay station module

Uninterruptable power supply (UPS) as a standalone device

Analog emergency telephone