beautypg.com

17 toner level sensor board (pwb-d), 17 toner level sensor board (pwb-d) -44 – Konica Minolta Magicolor 5440 DL User Manual

Page 81

background image

Other

Main Unit Field Service

2-44

II Main

tena

nce

Precautions for Reinstallation
• When reinstalling High Voltage

Unit/2, make sure that each color
connector is in the correct position,
as shown in the illustration on the
left.

4.4.17

Toner Level Sensor Board (PWB-D)

1.

Open the Front Door.

2.

Remove the Toner Cartridge and Waste Toner Bottle.

3.

Remove the Upper Front Cover and Right Front Cover.

2-30
4.

Remove the Control Panel.

2-34
5.

Remove the Exit Tray.

2-32
6.

Remove the Mechanical Control Board protective shield.

☞ Steps 1 to 4 on p.2-38 “Mechanical Control Board”

7.

Disconnect one connector (PJ13A)
[1] from the Mechanical Control
Board.

White

Yellow

Red

Blue

White

Red

Yellow

Red

Blue

White

4138fs2531e0

[1]

4138fs2532c0

5450_E.book_PDF.book 44 ページ 2005年4月12日 火曜日 午後12時54分