12 backup battery (magicolor 5450 only), 12 backup battery (magicolor 5450 only) -37 – Konica Minolta Magicolor 5440 DL User Manual
Page 74

Main Unit Field Service
Other
2-37
II Main
tena
nce
5.
Disconnect the two connectors [5] on
the Print Control Board.
6.
Disconnect the two flat cables [6]
from the Print Control Board.
7.
Remove five screws [7] and the Print
Control Board [8].
NOTE
• When the Print Control Board is
replaced, upgrade the Firmware to
the latest version.
☞ 2-23
8.
Remove three screws [9] and the
interface protective cover [4].
4.4.12
Backup Battery (magicolor 5450 only)
NOTE
• There is a risk of explosion if the battery is replaced with another one of an incor-
rect type. Dispose of used batteries according to the instructions.
• It is very important to protect the printer controller board and any associated cir-
cuit boards from electrostatic damage. Before performing this procedure, review
the removal of PWBs on page 2-28. In addition, always handle circuit boards by the
edges only.
1.
Remove the Rear Cover.
☞ 2-31
2.
Remove seven screws [1] and the
Print Control Board protective shield
[2].
[5]
[6]
4138F2E013DA
[7]
[9]
[8]
4138F2E014DA
4138fs2534c0
[1]
[1]
[1]
[2]
5450_E.book_PDF.book 37 ページ 2005年4月12日 火曜日 午後12時54分