1 restore factory default, Restore factory default -22 – Konica Minolta Magicolor 5440 DL User Manual
Page 125

Service Mode (magicolor 5430 DL/5440 DL)
Main Unit Field Service
3-22
III
Ad
just
men
t/Set
ting
5.3
Settings/Adjustments in Service/Service Person Mode
Functions
5.3.1
RESTORE FACTORY DEFAULT
Function
• Reinitializes the settings to their factory defaults.
Use
• To return the current settings to the factory default settings.
• Use this as the last resort before replacing the board when taking remedial steps for
a malfunction.
• The following table lists the items to be reinitialized and their default values.
NOTE
• Some items can be reset after being reinitialized while others cannot be.
A. Items that cannot be reset after reinitialization
*1: When the Duplex Option is installed
Item
Factory Default Value
Ref. Page
Counter:
Main Unit
Color
0
-
B/W
0
-
Total
0
-
Counter:
Duplex *1
Color
0
-
B/W
0
-
Total
0
-
Amount of toner still available
for use in each Toner Cartridge
100%
-
Transfer Roller use rate
0%
-
Transfer Belt use rate
0%
-
Fusing Unit use rate
0%
-
Waste Toner Bottle use rate
0%
-
Counter:Transfer Roller
0
-
Counter:Transfer Belt Unit
0
-
Counter:Fusing Unit
0
-
5450_E.book_PDF.book 22 ページ 2005年4月12日 火曜日 午後12時54分