beautypg.com

6 gradation reproduction failure, Gradation reproduction failure -38 – Konica Minolta Magicolor 5440 DL User Manual

Page 225

background image

Image Quality Problems

Main Unit Field Service

4-38

IV

T

roub

lshoo

t

in

g

5.1.6

Gradation reproduction failure

A. Typical Faulty Images

B. Troubleshooting Procedure

4036fs4048c0

4036fs4049c0

Step

Section

Check Item

Result

Action

1

Toner Cartridge Is the outside dirty?

YES

Clean.

2

PH Unit

Is the window surface dirty?

YES

Clean.

3

AIDC Sensor/Rt,

AIDC Sensor/Lt

Is the sensor dirty?

YES

Clean.

4

Has the problem been eliminated
through the checks of steps up to
3?

NO

Change the Toner Cartridge.
→ Change the PH Unit.

→ Change the AIDC Sensor.

→ Change High Voltage Unit/1.

→ Change High Voltage Unit/2.

5450_E.book_PDF.book 38 ページ 2005年4月12日 火曜日 午後12時54分