6 004ch: ozone ventilation fan motor malfunction, 7 004eh: lv cooling fan motor malfunction, 004ch: ozone ventilation fan motor malfunction -18 – Konica Minolta Magicolor 5440 DL User Manual
Page 205: 004eh: lv cooling fan motor malfunction -18

Malfunction code
Main Unit Field Service
4-18
IV
T
roub
lshoo
t
in
g
2.4.6
004CH: Ozone Ventilation Fan Motor malfunction
2.4.7
004EH: LV Cooling Fan Motor malfunction
Relevant Electrical Parts
Ozone Ventilation Fan Motor (M12)
Mechanical Control Board (PWB-A)
Step
Action
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the M12 connector for proper connection
and correct as necessary.
-
-
2
Check the fan for possible overload and correct
as necessary.
-
-
3
M12 operation check
PWB-A PJ6A-7 (LOCK)
PWB-A PJ6A-5 (ON)
14-I
4
Change PWB-A.
-
-
Relevant Electrical Parts
LV Cooling Fan Motor (M10)
Mechanical Control Board (PWB-A)
Step
Action
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the M10 connector for proper connection
and correct as necessary.
-
-
2
Check the fan for possible overload and correct
as necessary.
-
-
3
M10 operation check
PWB-A PJ9A-3 (LOCK)
PWB-A PJ9A-1 (ON)
12-J
4
Change PWB-A.
-
-
5450_E.book_PDF.book 18 ページ 2005年4月12日 火曜日 午後12時54分