Ac75 at command set – Siemens AC75 User Manual
Page 78
AC75 AT Command Set
2.14 AT^SCFG
s
AC75_ATC_V01.002
Page 78 of 569
10/30/06
Confidential / Released
shall be issued as escape sequences. A list of typical escape sequences can be found in Section
alphabet tables and UCS2 character values
. For example, the caret character "^" included in all Siemens
defined AT commands shall be given as "\1B\14".
After three minutes:
EXAMPLE 4
Usage of "AutoExec":
Deactivate a timer-driven Autoexec function configured at
2 (such as the periodic auto-
matic reset or the automatic switch-off functions configured in the preceding examples):
EXAMPLE 5
Usage of "URC/Ringline" and "URC/Datamode/Ringline":
AT^SCFG="AutoExec",1,1,0,0,"AT\1B\14SMSO","000:03:00"
^SCFG: "AutoExec","0","0","0","0",""
^SCFG:
"AutoExec","1","1","0","0","ATSMSO","000:
03:00","000:02:59"
Please note that the indication of the escape
sequence in the write command response depends
on the used program.
^SCFG: "AutoExec","0","1","1","0","","000:00:00","000:00:00"
^SCFG: "AutoExec","0","1","2","0","","000:00:00","000:00:00"
OK
^SCFG:"AutoExec",0,1,1,0,"AT^SMSO"
^SMSO: MS OFF
OK
^SHUTDOWN
Indicates that AT^SMSO was successfully executed.
The ME enters the POWER DOWN mode.
AT^SCFG="AutoExec",0,1,2
...
OK
AT+CSCS="GSM"
Switch to GSM character set.
OK
AT^SCFG?
Query all parameters.
...
^SCFG:"URC/Datamode/Ringline","off"
While the TA-TE link is reserved URCs will be indi-
cated by BREAK.
^SCFG:"URC/Ringline","local"
URCs on this interface will be indicated by Ring line
associated to the interface (e.g. RING0 for ASC0).
...
OK
AT^SCFG="URC/Datamode/Ringline","on"
^SCFG:"URC/Datamode/Ringline","on"
While the TA-TE link is reserved URCs will be indi-
cated by an activated "local" Ring line.
OK
AT^SCFG="URC/Ringline","asc0"
^SCFG:"URC/Ringline","asc0"
URCs on this interface will be indicated by an acti-
vated RING0 no matter whether or not the TA-TE link
is reserved.
OK
AT^SCFG="URC/Datamode/Ringline","off"
^SCFG:"URC/Datamode/Ringline","off"
URCs on this interface will be indicated by an acti-
vated RING0 if the TA-TE link is not reserved and by
BREAK if the TA-TE link is reserved.
OK
AT^SCFG="URC/Ringline"
Disable any Ring line indication for URCs on this
interface.
^SCFG:"URC/Ringline","off"
OK
- A75
- SXG75
- CX65
- A50
- C30
- A65
- SL75
- A35
- M75
- SX1
- C55
- M55
- SL45
- S65
- S75
- CF75
- CFX65
- AX75
- C75
- M65
- CX75
- ST60
- U15
- CF62
- C45
- C45
- Xelibri 8
- Xelibri 7
- SL42
- SL45i
- Xelibri 3
- ST55
- SL55
- C62
- C62
- Xelibri 6
- M50
- Xelibri 2
- Xelibri 4
- A57
- A36
- Xelibri 1
- Xelibri 5
- C70
- Gigaset SL 740
- Mobile Phone C35i
- 4110
- RS-485
- A55
- Gigaset SL55
- Gigaset C450 IP
- Gigaset E45
- S42
- Gigaset 150
- XT75
- SL370
- M30
- A40
- S56
- TDMA 800
- S40
- 150 H
- MT50
- C60
- SL 42
- CL50
- 1168
- C35i
- A52
- SL56
- A60
- SX66
- 4000
- MOVIEMATE 50
- XT55 AVL
- XT55
- 3000
- Gigaset 200
- Mobile
- Mux_guide_v06
- Gigaset S450 IP
- MC60
- Hicom 300E
- SF65
- CXV70
- CXV65
- 8WD44
- C61
- C56
- S45i
- MC55
- CX70
- PEGASUS-DTC AX72
- C70 CT70
- 4010
- Gigaset SL1
- Gigaset C100 DECT
- Gigaset S1
- 4000i
- Gigaset 3000 Classic