AC75 AT Command Set
22.5 AT^SFDL
s
AC75_ATC_V01.002
Page 533 of 569
10/30/06
Confidential / Released
22.5
AT^SFDL Enter Firmware Download Mode
The
command allows the application manufacturer to download AC75 firmware into the module by
starting the download process from the host application or a customer-designed download program. The down-
load can be done over the serial interfaces ASC0 or ASC1 or the USB interface.
For this purpose, the AC75 firmware update file must be available in the format *.USF. The file can be requested
from Siemens. The firmware file consists of records to be transferred one by one from the host application to the
module.
This manual only describes the handling of the
command. All technical requirements and steps to pre-
pare the host application for this download solution can be found in the Application Note "Updating Firmware".
An example for developing an appropriate download program is included.
The
write command causes the module to reset and enter the firmware update mode. This will be used
to read previous downloaded firmware data.
The
execute command causes the module to reset and enter the firmware download mode (this may
take some milliseconds). After entering the download mode the module sends the start pattern HEX 0x01
("ANSWER_OK") to the application to indicate its ready state. Next, the application shall start to send the records
of the firmware file. Each record received on the module is acknowledged to the host application. Once all
records are successfully received, the module shuts down automatically.
If the module is switched on although it has no valid firmware installed, it waits 60s for the
command
(or for another download method to be started). If neither the
command nor equivalent characters from
another download method are received the module switches off after a 60s timeout.
If a valid firmware is still installed, but the
command is issued without sending any firmware afterwards
the module will stay in ready state. In this case it must be switched off.
Syntax
Test Command
AT^SFDL=?
Response(s)
^SFDL:
(list of supported
s)
OK
Exec Command
AT^SFDL
Response(s)
OK
0x01
Write Command
AT^SFDL=
Response(s)
OK
ERROR
+CME ERROR:
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
-
+
+
+
-
-
-
-
+
+