AC75 AT Command Set

10.1 AT^SICS

s

AC75_ATC_V01.002

Page 257 of 569

10/30/06

Confidential / Released

Parameter Description

0...5

Internet connection profile identifier.

The

identifies all parameters of a connection profile, and,

when a service profile is created with

AT^SISS

the

needs

to be set as "conId" value of the

AT^SISS

parameter

.

Internet connection parameter.
“conType“

Type of Internet connection.

For supported values of

refer to

Type>

.

“alphabet“

Selects the character set for input and output of string parameters within a pro-

file.

The selected value is bound to the specific profile. This means that different

profiles may use different alphabets. Unlike other parameters the alphabet can

be changed no matter whether the

value "conType" has been

set.

For supported values of

refer to

alphabet>

.

“user“

User name string: maximum 32 characters (where "" is default).

“passwd“

Password string: maximum 32 characters (where ***** is default).

If

is "MsChapV1" then the maximum password

length is 16 characters.

“apn“

Access point name string value: maximum 100 characters (where "" is default).

“inactTO“

Inactivity timeout value in seconds: 0 ... 2

16

-1, default = 20

Number of seconds the bearer remains open although the service no longer

needs the bearer connection.

Do not set the timeout value below 3 sec. This may result in problems when

using the

(set in the last

AT^SISW

command to terminate an

upload data stream).

The value -1 indicates that, after opening the bearer with

AT^SICO

, the inac-

tivity timeout is currently disabled. Closing the bearer with

AT^SICC

restores

the previously set "inactTO" value of the concerned connection profile.

“calledNum“

Called BCD number.

“dataRate“

Data rate.

For supported values of

refer to

aRate>

.

“dataType“

Data call type.

For supported values of

refer to

dataType>

.

Write Command

AT^SICS=

,

,

Response(s)

OK

ERROR

+CME ERROR:

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

-

+

+

+

+

+

+

-

+

-

(num)

(str)