Autoexecatc, Autoexecperiod, Autoexecperiodtimeleft – Siemens AC75 User Manual
Page 64: Autoexec, Autoexecstate, Autoex, Ecatc, At a given, Autoexe, Catc
AC75 AT Command Set
2.14 AT^SCFG
s
AC75_ATC_V01.002
Page 64 of 569
10/30/06
Confidential / Released
AutoExec AT command String
This parameter specifies the AT command(s) to be launched automatically. Each AT command is executed in
the same way as if it were entered online, this means that command concatenation is possible if supported by
the given commands. If serial multiplex mode is activated (
) the first logical channel is used, i.e. CSD
calls (data or fax) could be set up. If the AC75 is busy on the serial channel command execution will be delayed
until ongoing action is finished.
The first two characters of the automatically launched AT command shall be "at".
Please refer to examples below.
Value will be saved while switching off the AC75 via AT commands (e.g.
or
) and restored
on next power up.
AutoExec Command Period
Parameter specifies the period after which
will be executed. Format is "hhh:mm:ss", where
characters indicate hours, minutes and seconds. This parameter applies to
=1 only.
Value will be saved while switching off the AC75 via AT commands (e.g.
or
) and restored
on next power up.
When using this feature with running java applications, please consider the minimum time for the execution of
is 15 seconds.
000:00:05...240:00:00
AutoExec Command Period Left
This parameter shows the amount of time left until
will be executed. Format is "hhh:mm:ss",
where characters indicate hours, minutes and seconds. This parameter applies to
=1 only.
Due to the internal activity and network signaling an execution delay of several seconds may occur for the overall
procedure.
000:00:00...240:00:00
AutoExec Command Status
This parameter is part of the Autoexec URC which is presented when a scheduled Autoexec activity is being
performed.
“1“
The value 1 indicates that the Autoexec activity specified with
is currently executed.
Bit
Mask
hex
Mask
dec
Control
D
0
D
1
0x00
0x01
0x02
0x03
0
1
2
3
00: Ignore ongoing calls
01: Wait until all calls have ended
10: Dismiss any ongoing call
11: RFU
D
2
0x04
4
0: One shot action
1: Periodic action (for "AutoExec/Period" only)
D
3
0x08
8
RFU
D
4
0x10
16
RFU
D
5
0x20
32
RFU
D
6
0x40
64
RFU
D
7
0x80
128
RFU
(str)(+CSCS)
(str)(+CSCS)
(str)(+CSCS)
(str)(+CSCS)