3 at^scpol polling configuration, Ac75 at command set – Siemens AC75 User Manual
Page 511

AC75 AT Command Set
20.3 AT^SCPOL
s
AC75_ATC_V01.002
Page 511 of 569
10/30/06
Confidential / Released
20.3
AT^SCPOL Polling Configuration
The
write command serves to start and stop polling a pin or port specified with
. The pin or
port must already be configured via
. Polling is only applicable to input pins.
After polling has been activated on a specified pin or port, all new values related to this pin or port will be reported
via the "
" URC.
Syntax
Unsolicited Result Code
^SCPOL:
Parameter Description
0
Suppress polling
1
Activate polling
already configured or a
already opened.
New value on this
.
0
Low for
1
0...1023
Test Command
AT^SCPOL=?
Response(s)
^SCPOL:
(list of supported
s), (list of supported
s)
OK
Write Command
Response(s)
OK
ERROR
+CME ERROR: 
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
-
+
+
+
+
+
+
-
+
-
(num)
(num)
(num)
- A75 (16 pages)
 - SXG75 (166 pages)
 - CX65 (75 pages)
 - A50 (77 pages)
 - C30 (31 pages)
 - A65 (58 pages)
 - SL75 (139 pages)
 - A35 (43 pages)
 - M75 (153 pages)
 - SX1 (103 pages)
 - C55 (110 pages)
 - M55 (140 pages)
 - SL45 (86 pages)
 - S65 (145 pages)
 - S75 (72 pages)
 - CF75 (150 pages)
 - CFX65 (77 pages)
 - AX75 (28 pages)
 - C75 (144 pages)
 - M65 (142 pages)
 - CX75 (152 pages)
 - ST60 (89 pages)
 - U15 (188 pages)
 - CF62 (122 pages)
 - C45 (82 pages)
 - Xelibri 8 (36 pages)
 - Xelibri 7 (31 pages)
 - SL45i (90 pages)
 - SL42 (96 pages)
 - Xelibri 3 (34 pages)
 - ST55 (88 pages)
 - SL55 (137 pages)
 - C62 (67 pages)
 - C62 (69 pages)
 - Xelibri 6 (30 pages)
 - M50 (96 pages)
 - Xelibri 2 (31 pages)
 - Xelibri 4 (31 pages)
 - A57 (37 pages)
 - A36 (43 pages)
 - Xelibri 1 (31 pages)
 - Xelibri 5 (30 pages)
 - C70 (144 pages)
 - Gigaset SL 740 (76 pages)
 - Mobile Phone C35i (2 pages)
 