AC75 AT Command Set

8.15 AT+CPOL

s

AC75_ATC_V01.002

Page 222 of 569

10/30/06

Confidential / Released

8.15

AT+CPOL Preferred Operator List

The

AT+CPOL

read command returns the list of the preferred operators. The

AT+CPOL

write command allows to

edit the list of the preferred operators. If

is given but

is left out, the entry is deleted. An

operator can be only once in the list.

Syntax

Parameter Description

The order number of the operator in the SIM preferred operator list.

2

Numeric format

Operator in numeric format (GSM Location Area Identification number which consists of a 3-digit country code

plus a 2- or 3-digit network code).

Test Command

AT+CPOL=?

Response(s)

+CPOL:

(list of supported

s), (list of supported

s)

OK

ERROR

+CME ERROR

Read Command

AT+CPOL?

Response(s)

+CPOL:

,

,

+CPOL:

...

OK

ERROR

+CME ERROR

Write Command

AT+CPOL=

[,

,

]

Response(s)

OK

ERROR

+CME ERROR:

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

GSM 07.07

+

+

+

+

+

+

+

-

+

-

(num)

(num)

(str)