1 at^sics internet connection setup profile, Table 10.1, Applicability of – Siemens AC75 User Manual
Page 256: At^sics, Ac75 at command set

AC75 AT Command Set
10.1 AT^SICS
s
AC75_ATC_V01.002
Page 256 of 569
10/30/06
Confidential / Released
10.1
AT^SICS Internet Connection Setup Profile
serves to create and edit Internet connection profiles. A connection profile can be assigned to one or
more service profiles defined with
, and thus, determines which type of connection is to be established
when opening a service profile with
The
read command requests the current settings of all Internet connection profiles. One line is issued
for every possible parameter of a given
"conType" value.
The
write command specifies all parameters of a connection profile identified by
At first the type of Internet connection needs to be selected via
value "conType". This deter-
mines the applicability of all other
values related to this "conType" and automatically sets their
defaults. An exception is the
which can be set before or after selecting "con-
Type".
To change the settings the write command needs to be executed for each single
parameters set with
are volatile.
Table 10.1: Applicability of
values
Syntax
value
CSD
GPRS0
"conType"
mandatory
mandatory
"user"
optional
optional
"passwd"
optional
optional
"apn"
ø
mandatory
"inactTO"
optional
optional
"calledNum"
mandatory
ø
"dataRate"
mandatory
ø
"dataType"
mandatory
ø
"authMode"
mandatory
optional
"fnur"
optional
optional
"dns1"
optional
optional
"dns2"
optional
optional
"alphabet"
optional
optional
Test Command
AT^SICS=?
Response(s)
OK
Read Command
AT^SICS?
Response(s)
OK