beautypg.com

At^snfm, Ac75 at command set – Siemens AC75 User Manual

Page 468

background image

AC75 AT Command Set

18.12 AT^SNFM

s

AC75_ATC_V01.002

Page 468 of 569

10/30/06

Confidential / Released

18.12

AT^SNFM Set microphone audio path and power supply

The

AT^SNFM

read command returns the microphone mute and supply voltage status.

The

AT^SNFM

write command can be used to switch the microphone's audio path (muted / not muted) or to con-

trol the power supply of the VMIC line for the two microphone inputs of the AC75 Module.

The microphone can be muted or activated by changing

in all audio modes (1 to 6) and during a

voice call only. As an alternative, you can use the

AT+CMUT

command to mute the microphone.

Syntax

Parameter Description

Microphone mute control parameter.

Evaluated only during voice calls and if

is omitted, e.g.

AT^SNFM

=1.

Command does not depend on audio mode.
0

Mutes the microphone.

1

(P)

Activates the microphone.

Microphone supply voltage control parameter. Controls the power supply VMIC of the two microphone inputs of

the AC75 Module.

CME error is given if

is not omitted. Enter for example

AT^SNFM

=,1 or

AT^SNFM

=,2.

0

Supply voltage is always switched off.

1

Supply voltage is always switched on.

2

(P)

Supply voltage state during voice calls is controlled by the ME. Actual value is

determined by parameter data set of the selected audio mode.

Test Command

AT^SNFM=?

Response(s)

^SNFM:

(list of supported

s) , (list of supported

s)

OK

Read Command

AT^SNFM?

Response(s)

^SNFM:

,

OK

Write Command

AT^SNFM=

[

][,

]

Response(s)

OK

ERROR

+CME ERROR:

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

-

+

+

+

+

+

+

-

+

-

(num)

(num)