163
- Enable/disable the Abnormal Event check box, to set the condition of the event for system to
alarm.
System Reboot: when the DVR system reboot without abnormal condition, the system
will send out the alarm message.
Abnormal Reboot: when the DVR system reboot in irregular condition, the system will
send out the alarm message.
Recording is switched off: when the recording has been stopped, the system will send
out the alarm message.
Network is switched off: when the network connection of DVR system is lost, the
system will send out the alarm message.
Hard Disk failed: when the hard disk
doesn’t work normally, the system will send out
the alarm message.
S.M.A.R.T.:
select the risk level (High or Low) that base on the DVR system’s S.M.A.R.T.
mechanism to detect the hard disk’s status and the system will send out the alarm
message when the status has matched the selected risk level.
Temperature: set a temperature limited of system for system to alarm. When DVR
system temperature is over the temperature limited, the
system will send out the alarm. The system supports °C
and °F temperature mode.
Illegal Entry: any objects move between selected
regions which user has set up in Object Counting
section (see
), the system will send out
the alarm. Select the entry (object moves from region 1
to 2 or from region 2 to 1) and click the Detail to select
the camera and the times for system alarm.