beautypg.com

Equipment table, Object inspector – Biamp LTR User Manual

Page 73

background image

Software Tools

Equipment Table

Provides a table of NEXIA devices used in the system design. Devices are automatically added
to the Equipment Table whenever

CS

,

PM

,

SP

,

VC

, or

TC

blocks are placed into the Layout.

When

connected to the network

, specific hardware devices may be chosen (by Serial #) for use

in the system. When

connected to the system

, Serial # and Device Description Label becomes

'read-only' information.

An RCB tab at the lower-left of the Equipment Table dialog box provides an editable table of
devices connected to the

Remote Control Bus

of the NEXIA devices in the system design. This

table is used to establish proper association between external physical controls and their
corresponding component counterparts in the layout. Each DevID (control component) should
be matched to an appropriate Serial # (physical control). The DevID number can be found in the
right corner of control component objects in the layout, when 'Display Device Assignment in
DSP Block Info Field' is selected from

Display Options

. Serial # and Device Description Label

information can be found for the physical controls using

Device Maintenance

.

Object Inspector

Provides a list of all objects within the Layout, along with their Object Codes,

Text Labels, Unit numbers, Instance ID numbers, and Instance ID Tags.